Ask Mallard
Core concept

Choosing a run chart or control chart

5 min read

Use a run chart to examine time-order patterns around a median; use a suitable control chart to compare observations with expected process variation.

Fit

When it matters, and when it does not

It matters when

  • You measure a process repeatedly in time order.
  • You need to separate a possible process change from ordinary variation.

It matters less when

Before you start

What to check in your study

Decide these first
  1. The measure and its denominatorDistinguish continuous values, proportions and event rates. Chart choice depends on that distinction.
  2. A baseline periodDefine a period that can reasonably represent a stable process.
  3. Signal rules and planned responsesChoose rules before inspecting changes. Record interventions and data changes in time order.
It rests on these
  1. The definition and collection of the measure remain comparable.How to check: Check case mix, denominators and missing data before interpreting a signal.
  2. A control chart model fits the process.How to check: Check dependence, extra spread and baseline stability. Serial correlation can cause false signals.

Plain language

How it works

A run chart joins observations in time order and uses a median with stated rules for runs or crossings. It does not have calculated control limits. Rule sets differ in false-signal rates and sensitivity.

The choice at a glance
Time-order patterns: Median and stated run rules leads to Run chart: no control limits; Model-based signals: Stable baseline and suitable process model leads to Control chart: calculated limits; Clinical acceptability: A threshold chosen for clinical reasons leads to Target: separate from chart limits.Time-order patternsMedian and stated run rulesRun chart: no control limitsUse the study question and assumptions together.Model-based signalsStable baseline and suitable process modelControl chart: calculated limitsUse the study question and assumptions together.Clinical acceptabilityA threshold chosen for clinical reasonsTarget: separate from chart limitsUse the study question and assumptions together.
Conceptual diagram. It shows the structure of the idea, not data from any study.
Reading the choice

A control chart adds a center line and limits from a specified process model. Use a chart for individual continuous values, proportions, counts or rates as appropriate. For a p-chart, limits change when the denominator changes.

What decides it

Control limits describe expected process behavior. They are neither confidence intervals for an average nor acceptable clinical thresholds. Both charts support monitoring; neither alone separates an intervention from other changes happening at the same time.

A median-based run chart
A run chart over time with a center line at the median of the points. Early points scatter below and around it; later points form a sustained run above it, which signals a shift.A run chart: a sustained run on one side of the center line signals a shiftTimeMeasureCenter line (median)Run above the center lineA signal says the process probably changed, not why. A run chart has no control limits; those are what acontrol chart adds.
Conceptual diagram. It shows the structure of the idea, not data from any study.

Worked example

A worked example

Invented for illustration
Setting
A clinic monitors a binary delay outcome each week.
Question
Are control limits the same as a performance target?
Approach
A stable baseline has 10 delays per 100 visits. Each future week also has 100 independent visits.
Result
The baseline is 10 in 100. A simple p-chart has approximate three-standard-deviation limits of 1 and 19 in 100.
What it means
A clinical target can differ from both limits. These illustrative limits assume binomial variation; they do not measure uncertainty in the baseline estimate.

In practice

Recent studies PubMed search · not vetted

Searching PubMed…

Watch out

Common mistakes

The one to remember

Control limits describe process variation, not clinical targets or confidence intervals. A chart signal alone does not establish what caused a change.

  • Calling a point outside a limit proof of improvement.Instead: Investigate the signal, its direction and possible data changes. The chart does not identify the cause.
  • Moving the center line after every unusual point.Instead: Use a documented rule for establishing a new stable phase. Do not redraw limits merely to erase signals.

Inside Mallard

How Mallard uses this

Mallard lists Choosing a run chart or control chart under Core research concepts.

No Mallard code example points to this page.
Atlas node concept.choosing_run_vs_control, the id a plan cue records.

Related Learn pages

Related designs and methods

Evidence

Sources & further reading

  1. Run charts revisited: a simulation study of run chart rules for detection of non-random variation in health care processes (opens in a new tab) · PLoS One · doi 10.1371/journal.pone.0113825
  2. Large-scale empirical optimisation of statistical control charts to detect clinically relevant increases in surgical site infection rates (opens in a new tab) · BMJ Qual Saf · doi 10.1136/bmjqs-2018-008976
  3. The run chart: a simple analytical tool for learning from variation in healthcare processes (opens in a new tab) · BMJ Qual Saf · doi 10.1136/bmjqs.2009.037895
Prepared with AI assistance. Source titles, authors, publication years and available DOIs were verified against PubMed on 2026-11-06. No independent professional approval is claimed. Anhøj and Olesen evaluate run-chart rules by simulation. Ilieş and colleagues optimize control-chart detection in infection data. Perla and colleagues explain the run-chart workflow.
Last source review: 2026-11-06
AI-generated educational content
Mallard uses reputable methodological and reporting sources, but this material may contain errors or omit important context. Verify important methodological decisions with the cited sources and, when appropriate, a qualified research methodologist or statistician.